CipherLab 1564 Dokumentacja

Przeglądaj online lub pobierz Dokumentacja dla Czytniki kodów kreskowych CipherLab 1564. CipherLab 1564 Specifications Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 267
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów

Podsumowanie treści

Strona 1 - 1664 Barcode Scanne

1664 Barcode Scanner Setup barcodes included. Version 1.03

Strona 2

1664 Barcode Scanner User Guide 4.21.5 GS1-128 Emulation Mode for UCC/EAN Composite Codes...154 4.22 US Postal C

Strona 3 - IMPORTANT NOTICES

89 Update Chapter 2 Selecting Output Interface *Capital Lock OFF

Strona 4

90 Enter Setup 1664 Barcode Scanner User Guide Alphabet Transmission By default, the alphabet transmission is case-sensitive, meaning that the alphab

Strona 5 - RELEASE NOTES

91 Update Chapter 2 Selecting Output Interface Numeric Transmission By default, the alphanumeric keypad is used for transmitting numerics. Sel

Strona 6 - CONTENTS

92 Enter Setup 1664 Barcode Scanner User Guide 2.6.3 INTER-CHARACTER DELAY By default, the inter-character delay is set to zero. Specify a value, ran

Strona 7

93 Update Chapter 2 Selecting Output Interface 2.6.5 HID CHARACTER TRANSMIT MODE By default, HID interface sends data to the host in batch, or

Strona 8

94 Enter Setup 1664 Barcode Scanner User Guide 2.7 DIRECT USB VIRTUAL COM 1664 supports “Direct” USB Virtual COM interface for memory mode. Use the p

Strona 9

95 Update Chapter 2 Selecting Output Interface 2.7.3 ACK/NAK TIMEOUT By default, the scanner sends data to the host without waiting for an ACK

Strona 10

96 Enter Setup 1664 Barcode Scanner User Guide

Strona 11

97 Update The scanner can be configured to send data to a host computer wirelessly via the 3610 dongle, or to a notebook computer or PDA with Blu

Strona 12 - INTRODUCTION

98 Enter Setup 1664 Barcode Scanner User Guide 3.1 CONNECTING VIA 3610 By default, the interface of 3610 is set to “USB HID”. You can have up to seve

Strona 13

1664 Barcode Scanner User Guide 6.2.2 Restore Default Format ...

Strona 14 - CHARGING THE BATTERY

99 Update Chapter 3 Setting up a WPAN Connection 3.1.2 CHANGE INTERFACE If want to change the interface 3610, use one of the connected scanner

Strona 15

100 Enter Setup 1664 Barcode Scanner User Guide 3.1.3 CONFIGURE RELATED SETTINGS Sniff Mode (Power-saving) By default, this feature is enabled, meani

Strona 16 - USING 3610

101 Update Chapter 3 Setting up a WPAN Connection 3.2 CONNECTING VIA BLUETOOTH® DONGLE 3.2.1 CHANGE INTERFACE Below is the procedure to config

Strona 17

102 Enter Setup 1664 Barcode Scanner User Guide 3.2.2 CONFIGURE RELATED SETTINGS Sniff Mode (Power-saving) By default, this feature is enabled, meani

Strona 18 - SYMBOLOGIES SUPPORTED

103 Update Chapter 3 Setting up a WPAN Connection Authentication When any changes are made to authentication and PIN code on the scanner side,

Strona 19

104 Enter Setup 1664 Barcode Scanner User Guide Note: When using Bluetooth® HID, some device driver may not support pre-defined PIN c

Strona 20 - QUICK START

105 Update Chapter 3 Setting up a WPAN Connection 3.2.3 CONNECT TO DONGLE The procedure goes through associating devices for establishing a WP

Strona 21

106 Enter Setup 1664 Barcode Scanner User Guide 4. Turn on the scanner with correct WPAN settings, such as select Bluetooth® SPP or Bluetooth® HID,

Strona 22 - EXIT CONFIGURATION MODE

107 Update Chapter 3 Setting up a WPAN Connection 7. Click [Next]. 8. Enter the passkey for authentication, which must be exactly the same a

Strona 23

108 Enter Setup 1664 Barcode Scanner User Guide 9. Click [Next]. Wait for a few seconds for Windows to exchange passkeys.

Strona 24

1 Update CipherLab’s small-form-factor 1600 Series Barcode Scanners are specifically designed to answer the mobile demands. The palm-sized scanne

Strona 25

109 Update Chapter 3 Setting up a WPAN Connection Note: When Bluetooth security is enabled without providing a pre-set PIN code, dynamic inpu

Strona 26

110 Enter Setup 1664 Barcode Scanner User Guide 11. Now the target scanner will be listed as shown below. You can have up to seven scanners connecte

Strona 27 -  Refer to Appendix III

111 Update Chapter 3 Setting up a WPAN Connection Bluetooth®SPP Connected Bluetooth®SPP Disconnected

Strona 28 - LIST THE CURRENT SETTINGS

112 Enter Setup 1664 Barcode Scanner User Guide

Strona 29

113 Update In this chapter, a brief on the symbology settings is provided for your reference. IN THIS CHAPTER 4.1 Codabar ...

Strona 30

114 Enter Setup 1664 Barcode Scanner User Guide 4.1 CODABAR *Enable Disable 4.1.1 START/STOP TRANSMISSION Decide whether to include the start

Strona 31

115 Update Chapter 4 Changing Symbology Settings 4.1.3 CODE LENGTH QUALIFICATION To prevent the "short scan" error, define the "

Strona 32 - Chapter 1

116 Enter Setup 1664 Barcode Scanner User Guide 4.2 CODE 25 – INDUSTRIAL 25 *Enable Disable

Strona 33 - Turn off the scanner…

117 Update Chapter 4 Changing Symbology Settings 4.2.1 CODE LENGTH QUALIFICATION To prevent the "short scan" error, define the "

Strona 34

118 Enter Setup 1664 Barcode Scanner User Guide 4.3 CODE 25 – INTERLEAVED 25 *Enable Disable 4.3.1 VERIFY CHECK DIGIT Decide whether to verif

Strona 35 -  For Bluetooth

2 Enter Setup 1664 Barcode Scanner User Guide GETTING FAMILIARIZED WITH 1664 AND 3610 INSTALLING THE BATTERY INTO 1664 1) Hold the scanner face down

Strona 36

119 Update Chapter 4 Changing Symbology Settings 4.3.3 CONVERT TO EAN-13 Decide whether to convert a 14-character barcode into EAN-13 if the f

Strona 37 - 1.2.1 TRANSMIT BUFFER

120 Enter Setup 1664 Barcode Scanner User Guide 4.3.4 CODE LENGTH QUALIFICATION To prevent the "short scan" error, define the "Length

Strona 38 - 1.2.2 MEMORY MODE

121 Update Chapter 4 Changing Symbology Settings 4.4 CODE 25 – MATRIX 25 Enable *Disable 4.4.1 VERIFY CHECK DIGIT Decide whether to ve

Strona 39

122 Enter Setup 1664 Barcode Scanner User Guide 4.4.3 CODE LENGTH QUALIFICATION To prevent the "short scan" error, define the "Length

Strona 40

123 Update Chapter 4 Changing Symbology Settings 4.5 CODE 25 – CHINESE 25 Enable *Disable

Strona 41 - 1.3.2 GOOD READ LED DURATION

124 Enter Setup 1664 Barcode Scanner User Guide 4.6 ITALIAN PHARMACODE (CODE 32) Enable *Disable Note: Code 39 must be enabled first.

Strona 42 - Meaning

125 Update Chapter 4 Changing Symbology Settings 4.7 CODE 39 *Enable Disable 4.7.1 VERIFY CHECK DIGIT Decide whether to verify the che

Strona 43 - 1.4.1 BEEPER VOLUME

126 Enter Setup 1664 Barcode Scanner User Guide 4.7.3 STANDARD/FULL ASCII CODE 39 Decide whether to support Code 39 Full ASCII that includes all the

Strona 44 - 1.4.2 GOOD READ BEEP

127 Update Chapter 4 Changing Symbology Settings 4.7.4 CODE LENGTH QUALIFICATION To prevent the "short scan" error, define the "

Strona 45 - 1.5.1 GOOD READ VIBRATOR

128 Enter Setup 1664 Barcode Scanner User Guide 4.8 TRIOPTIC CODE 39 Decide whether to decode Trioptic Code 39.  Trioptic Code 39 is a variant of C

Strona 46 - 1.6 SEND “NR” TO HOST

3 Update Introduction Note: (1) To turn off the scanner, press the [Power/Delete] key for 2 seconds. The scanne

Strona 47 - 1.7.1 LASER MODE

129 Update Chapter 4 Changing Symbology Settings 4.9 CODE 93 *Enable Disable

Strona 48 - 1.7.3 AUTO POWER OFF MODE

130 Enter Setup 1664 Barcode Scanner User Guide 4.9.1 CODE LENGTH QUALIFICATION To prevent the "short scan" error, define the "Length

Strona 49 - 1.7.5 MULTI-BARCODE MODE

131 Update Chapter 4 Changing Symbology Settings 4.10 CODE 128 *Enable Disable

Strona 50

132 Enter Setup 1664 Barcode Scanner User Guide 4.11 GS1-128 (EAN-128) *Enable Disable Note: GS1-128 barcodes can be decoded only when this

Strona 51 -  Auto Power Off mode

133 Update Chapter 4 Changing Symbology Settings 4.12 ISBT 128 *Enable Disable 4.12.1 ISBT CONCATENATION Decide whether to decode and

Strona 52

134 Enter Setup 1664 Barcode Scanner User Guide 4.12.2 ISBT CONCATENATION REDUNDANCY Specify the concatenation redundancy (2~20 times) when ISBT conc

Strona 53 - 1.12 NEGATIVE BARCODES

135 Update Chapter 4 Changing Symbology Settings 4.13 GS1 DATABAR (RSS FAMILY) It is categorized into three groups: Group I — GS1 DataBar Omn

Strona 54

136 Enter Setup 1664 Barcode Scanner User Guide 4.13.2 GS1 DATABAR OMNIDIRECTIONAL (RSS-14) Enable RSS-14 & RSS Expanded (Groups I, II) *D

Strona 55 -  Bluetooth

137 Update Chapter 4 Changing Symbology Settings 4.13.3 GS1 DATABAR EXPANDED (RSS EXPANDED) Enable RSS-14 & RSS Expanded (Groups I, II)

Strona 56

138 Enter Setup 1664 Barcode Scanner User Guide 4.13.4 GS1 DATABAR LIMITED (RSS LIMITED) Enable RSS Limited (Group III) *Disable Transmit Cod

Strona 57

4 Enter Setup 1664 Barcode Scanner User Guide CHARGING THE BATTERY VIA CHARGER The battery charger is provided for charging the battery outside of th

Strona 58

139 Update Chapter 4 Changing Symbology Settings 4.13.5 CONVERT TO UPC/EAN This only applies to GS1 DataBar Omnidirectional and GS1 DataBar Li

Strona 59 - 1.16.3 DATE FORMAT

140 Enter Setup 1664 Barcode Scanner User Guide 4.14 MSI Enable *Disable 4.14.1 VERIFY CHECK DIGIT Select one of the three calculations to ve

Strona 60 - 1.17.2 DECODING ILLUMINATION

141 Update Chapter 4 Changing Symbology Settings 4.14.3 CODE LENGTH QUALIFICATION To prevent the "short scan" error, define the &quo

Strona 61 - 1.18.2 RESET CONNECTION

142 Enter Setup 1664 Barcode Scanner User Guide 4.15 EAN-8 EAN-8 *Enable EAN-8 (No Addon) Disable EAN-8 Addon 2 Enable EAN-8 Addon 2

Strona 62 - Chapter 2

143 Update Chapter 4 Changing Symbology Settings 4.16 EAN-13 EAN-13 *Enable EAN-13 (No Addon) Disable EAN-13 Addon 2 Enable EAN-13

Strona 63 - 2.1 BLUETOOTH

144 Enter Setup 1664 Barcode Scanner User Guide 4.16.1 CONVERT TO ISBN Decide whether to convert the EAN-13 barcode, starting with 978 and 979, to IS

Strona 64 - 2.1.1 ACTIVATE BLUETOOTH

145 Update Chapter 4 Changing Symbology Settings 4.17 UCC COUPON EXTENDED CODE Decide whether to decode the following barcodes as Coupon Code.

Strona 65 - 2.1.2 RESET CONNECTION

146 Enter Setup 1664 Barcode Scanner User Guide 4.18 UPC-A UPC-A *Enable UPC-A (No Addon) Disable UPC-A Addon 2 Enable UPC-A Addon 2

Strona 66

147 Update Chapter 4 Changing Symbology Settings 4.18.1 TRANSMIT SYSTEM NUMBER Decide whether to include the system number in the data being t

Strona 67 -

148 Enter Setup 1664 Barcode Scanner User Guide 4.19 UPC-E UPC-E *Enable UPC-E (No Addon) Disable UPC-E Addon 2 Enable UPC-E Addon 2

Strona 68

5 Update Introduction USING 3610 The CipherLab Dongle(3610) is specifically designed for the scanner to communicate with a host computer cordle

Strona 69 - Cap Lock Type Description

149 Update Chapter 4 Changing Symbology Settings 4.19.1 SELECT SYSTEM NUMBER Decide whether to decode the ordinary UPC-E barcodes only or both

Strona 70

150 Enter Setup 1664 Barcode Scanner User Guide 4.19.3 TRANSMIT SYSTEM NUMBER Decide whether to include the system number in the data being transmitt

Strona 71

151 Update Chapter 4 Changing Symbology Settings 4.20 CODE 11 Enable *Disable 4.20.1 VERIFY CHECK DIGIT Decide whether to verify the c

Strona 72

152 Enter Setup 1664 Barcode Scanner User Guide 4.20.3 CODE LENGTH QUALIFICATION To prevent the "short scan" error, define the "Length

Strona 73 - 2.1.5 INTER-FUNCTION DELAY

153 Update Chapter 4 Changing Symbology Settings 4.21 COMPOSITE CODE 4.21.1 COMPOSITE CC-A/B Enable Composite CC-A/B *Disable 4.21.2 C

Strona 74

154 Enter Setup 1664 Barcode Scanner User Guide 4.21.4 UPC COMPOSITE MODE UPC barcodes can be “linked” with a 2D barcode during transmission as if th

Strona 75

155 Update Chapter 4 Changing Symbology Settings 4.22 US POSTAL CODE 4.22.1 US POSTNET *Enable US Postnet Disable 4.22.2 US PLANET

Strona 76 - 2.2.3 ACK/NAK TIMEOUT

156 Enter Setup 1664 Barcode Scanner User Guide 4.23 UK POSTAL CODE 4.23.1 UK POSTAL *Enable UK Postal Disable 4.23.2 TRANSMIT CHECK DIGIT De

Strona 77

157 Update Chapter 4 Changing Symbology Settings 4.24 MORE POSTAL CODE 4.24.1 JAPAN POSTAL *Enable Japan Postal Disable 4.24.2 AUSTRAL

Strona 78 - Exit SPP Master Mode

158 Enter Setup 1664 Barcode Scanner User Guide 4.24.5 UPU FICS POSTAL Enable UPU FICS Postal *Disable

Strona 79 - 2.3.2 INTER-FUNCTION DELAY

6 Enter Setup 1664 Barcode Scanner User Guide INSIDE THE PACKAGE The items included in the package may be different, depending on your order. Save th

Strona 80 - 2.3.3 ACK/NAK TIMEOUT

159 Update Chapter 4 Changing Symbology Settings 4.25 2D SYMBOLOGIES 4.25.1 PDF417 *Enable PDF417 Disable 4.25.2 MicroPDF417 Enable

Strona 81 - 2.4 USB HID VIA 3610

160 Enter Setup 1664 Barcode Scanner User Guide 4.25.3 DATA MATRIX *Enable Data Matrix Disable Data Matrix Mirror Decide whether to decode m

Strona 82

161 Update Chapter 4 Changing Symbology Settings 4.25.4 MAXICODE *Enable Maxicode Disable 4.25.5 QR CODE *Enable QR Code Disabl

Strona 83

162 Enter Setup 1664 Barcode Scanner User Guide 4.26 MACRO PDF Macro PDF is a special feature for concatenating multiple PDF barcodes into one file,

Strona 84

163 Update Chapter 4 Changing Symbology Settings 4.26.2 ESCAPE CHARACTERS When enabled, it uses the backslash "\" as an Escape chara

Strona 85

164 Enter Setup 1664 Barcode Scanner User Guide

Strona 86

165 Update You may configure the format of the collected data output to the host computer. Barcodes read by the scanner will be processed in the

Strona 87

166 Enter Setup 1664 Barcode Scanner User Guide 5.2 CHARACTER SUBSTITUTION Character substitution is performed on every occurrence of the first chara

Strona 88

167 Update Chapter 5 Defining Output Format 5.2.1 SELECT A SET FOR CHARACTER SUBSTITUION Configure Set 1 Configure Set 2 Configure

Strona 89

168 Enter Setup 1664 Barcode Scanner User Guide 5.2.2 SYMBOLOGIES FOR CHARACTER SUBSTITUTION (ALL 3 SETS) By default character substitution will be p

Strona 90 - 2.4.4 INTER-FUNCTION DELAY

7 Update Introduction SYMBOLOGIES SUPPORTED Most of the popular barcode symbologies are supported, as listed below. Each can be individually en

Strona 91

169 Update Chapter 5 Defining Output Format Character Substitution for Code 128 *Apply Do Not Apply Character Substitution for GS1-128

Strona 92 - 2.5.2 INTER-FUNCTION DELAY

170 Enter Setup 1664 Barcode Scanner User Guide Character Substitution for EAN-8 Addon 5 *Apply Do Not Apply Character Substitution for EAN-1

Strona 93 - 2.5.3 ACK/NAK TIMEOUT

171 Update Chapter 5 Defining Output Format Character Substitution for Industrial 25 *Apply Do Not Apply Character Substitution for In

Strona 94 - 2.6 DIRECT USB HID

172 Enter Setup 1664 Barcode Scanner User Guide Character Substitution for GS1 DataBar *Apply Do Not Apply Character Substitution for UPC-A (

Strona 95

173 Update Chapter 5 Defining Output Format Character Substitution for UPC-E Addon 2 *Apply Do Not Apply Character Substitution for UP

Strona 96

174 Enter Setup 1664 Barcode Scanner User Guide Character Substitution for Composite CC-C *Apply Do Not Apply Character Substitution for Comp

Strona 97

175 Update Chapter 5 Defining Output Format Character Substitution for Japan Postal *Apply Do Not Apply Character Substitution for Aus

Strona 98

176 Enter Setup 1664 Barcode Scanner User Guide Character Substitution for PDF417 *Apply Do Not Apply Character Substitution for MicroPDF417

Strona 99

177 Update Chapter 5 Defining Output Format Character Substitution for MicroQR *Apply Do Not Apply Character Substitution for Aztec

Strona 100 - *Capital Lock OFF

178 Enter Setup 1664 Barcode Scanner User Guide 5.3 PREFIX/SUFFIX CODE By default, there is no prefix code, and [ENTER] or [CR] (Carriage Return) is

Strona 101 - Alphabet Transmission

8 Enter Setup 1664 Barcode Scanner User Guide GS1 DataBar Limited (RSS Limited) Disabled GS1 DataBar Expanded (RSS Expanded) Disabled GS1 DataB

Strona 102

179 Update Chapter 5 Defining Output Format 5.4 CODE ID Up to two characters for Code ID can be configured for each symbology. To make the Cod

Strona 103 - 2.6.4 INTER-FUNCTION DELAY

180 Enter Setup 1664 Barcode Scanner User Guide Code ID options Set 1 Set 2 Set 3 Set 4 Set 5 Code 39 A C Y M A Trioptic Code 39 A C Y

Strona 104

181 Update Chapter 5 Defining Output Format MicroQR f T R Y Q Aztec g U Q Z z IATA z z r h S Macro PDF417 p i a q L Macro MicroPDF417 q

Strona 105 - 2.7.2 INTER-FUNCTION DELAY

182 Enter Setup 1664 Barcode Scanner User Guide 5.4.2 CHANGE CODE ID 1) Read the barcode below to change code ID of a specific symbology. 2) Read t

Strona 106 - 2.7.3 ACK/NAK TIMEOUT

183 Update Chapter 5 Defining Output Format Configure Code ID for Interleaved 25 Configure Code ID for Matrix 25 Configure Code ID

Strona 107 - Enter Setup

184 Enter Setup 1664 Barcode Scanner User Guide Configure Code ID for US Planet Configure Code ID for UK Postal Configure Code ID for Japa

Strona 108 - Chapter 3

185 Update Chapter 5 Defining Output Format Configure Code ID for MicroQR Configure Code ID for Aztec Configure Code ID for IATA

Strona 109 -  “Serial Number” label

186 Enter Setup 1664 Barcode Scanner User Guide 5.5 LENGTH CODE A 4-digit code representing the length of barcode data (character count) can be inser

Strona 110 - 3.1.2 CHANGE INTERFACE

187 Update Chapter 5 Defining Output Format Length Code for Code 128 Apply *Do Not Apply Length Code for GS1-128 & GS1 DataBar

Strona 111 - Sniff Mode (Power-saving)

188 Enter Setup 1664 Barcode Scanner User Guide Length Code for Italian Pharmacode Apply *Do Not Apply Length Code for Industrial 25 Apply

Strona 112 - 3.2.1 CHANGE INTERFACE

Copyright © 2011~2012 CIPHERLAB CO., LTD. All rights reserved The software contains proprietary information of CIPHERLAB CO., LTD.; it is provided un

Strona 113

9 Update The configuration of the scanner can be done by reading the setup barcodes contained in this manual or via the ScanMaster software. Th

Strona 114 - Authentication

189 Update Chapter 5 Defining Output Format Length Code for MSI Apply *Do Not Apply Length Code for UPC-A Apply *Do Not Apply

Strona 115

190 Enter Setup 1664 Barcode Scanner User Guide Length Code for Composite CC-A/B Apply *Do Not Apply Length Code for Composite CC-C Apply

Strona 116 - 3.2.3 CONNECT TO DONGLE

191 Update Chapter 5 Defining Output Format Length Code for UK Postal Apply *Do Not Apply Length Code for Japan Postal Apply *D

Strona 117

192 Enter Setup 1664 Barcode Scanner User Guide Length Code for UPU FICS Postal Apply *Do Not Apply Length Code for PDF417 Apply *Do N

Strona 118 - 107

193 Update Chapter 5 Defining Output Format Length Code for QR Code Apply *Do Not Apply Length Code for MicroQR Apply *Do Not A

Strona 119

194 Enter Setup 1664 Barcode Scanner User Guide 5.6 MULTI-BARCODE EDITOR The Multi-Barcode Editor allows deciding the output sequence of a concatenat

Strona 120 - 109

195 Update Chapter 5 Defining Output Format 5.6.1 EDIT A CONCATENATION OF BARCODES Edit Output Sequence 1) Read the barcode above to star

Strona 121

196 Enter Setup 1664 Barcode Scanner User Guide 79 (y) Chinese 25 5A (Z) N/A 7A (z) Aztec 5B ( [ ) GS1 DataBar (RSS) 7B ({) Micro QR 7

Strona 122

197 Update Chapter 5 Defining Output Format 5.6.2 ACTIVATE THE CONCATENATION OF BARCODES By default, the output sequence editing of the concat

Strona 123

198 Enter Setup 1664 Barcode Scanner User Guide 5.7 REMOVAL OF SPECIAL CHARACTER You can only specify 1 character, but it will remove every matching

Strona 124 - Chapter 4

10 Enter Setup 1664 Barcode Scanner User Guide Working Mode Upon powering up, the scanner will try to establish a connection with 3610 or a computer

Strona 125 - 4.1.2 CLSI CONVERSION

199 Update The scanner allows advanced data editing by applying user-configured editing formats. The whole processed data can be divided into fie

Strona 126

200 End Programming Format 1664 Barcode Scanner User Guide 6.1 ACTIVATING EDITING FORMATS 6.1.1 ACTIVATE EDITING FORMATS If you have already configu

Strona 127 - 4.2 CODE 25 – INDUSTRIAL 25

201 Update Chapter 6 Applying Formats for Data Editing Editing Format 5 Enable *Disable 6.1.2 EXCLUSIVE DATA EDITING By default, only

Strona 128

202 End Programming Format 1664 Barcode Scanner User Guide 6.2 HOW TO CONFIGURE EDITING FORMATS

Strona 129 - 4.3.2 TRANSMIT CHECK DIGIT

203 Update Chapter 6 Applying Formats for Data Editing 6.2.1 SELECT FORMAT TO CONFIGURE Start Programming Format Select one editing format (Fo

Strona 130 - 4.3.3 CONVERT TO EAN-13

204 End Programming Format 1664 Barcode Scanner User Guide 6.2.2 RESTORE DEFAULT FORMAT You may select an existing editing format and have the defau

Strona 131

205 Update Chapter 6 Applying Formats for Data Editing 6.3 CONFIGURING FORMAT — DEFINE DATA CRITERIA Three applicable conditions can be config

Strona 132 - 4.4.2 TRANSMIT CHECK DIGIT

206 End Programming Format 1664 Barcode Scanner User Guide Editing Format for Codabar *Apply Do Not Apply Editing Format for Code 39 *App

Strona 133

207 Update Chapter 6 Applying Formats for Data Editing Editing Format for GS1-128 & GS1 DataBar *Apply Do Not Apply Editing Format

Strona 134 - 4.5 CODE 25 – CHINESE 25

208 End Programming Format 1664 Barcode Scanner User Guide Editing Format for EAN-13 *Apply Do Not Apply Editing Format for EAN-13 Addon 2

Strona 135

11 Update Quick Start ENTER CONFIGURATION MODE For the scanner to enter the configuration mode, read the "Enter Setup" barcode, which

Strona 136 - 4.7.2 TRANSMIT CHECK DIGIT

209 Update Chapter 6 Applying Formats for Data Editing Editing Format for Interleaved 25 *Apply Do Not Apply Editing Format for Matrix

Strona 137

210 End Programming Format 1664 Barcode Scanner User Guide Editing Format for UPC-A Addon 2 *Apply Do Not Apply Editing Format for UPC-A Add

Strona 138

211 Update Chapter 6 Applying Formats for Data Editing Editing Format for UCC Coupon Extended Code *Apply Do Not Apply Editing Format

Strona 139 - 4.8 TRIOPTIC CODE 39

212 End Programming Format 1664 Barcode Scanner User Guide Editing Format for US Postnet *Apply Do Not Apply Editing Format for US Planet

Strona 140 - 4.9 CODE 93

213 Update Chapter 6 Applying Formats for Data Editing Editing Format for Dutch Postal *Apply Do Not Apply Editing Format for USPS 4CB

Strona 141

214 End Programming Format 1664 Barcode Scanner User Guide Editing Format for Data Matrix *Apply Do Not Apply Editing Format for Maxicode

Strona 142 - 4.10 CODE 128

215 Update Chapter 6 Applying Formats for Data Editing 6.3.2 DATA LENGTH The length must include prefix, suffix (0x0d by default), length code

Strona 143 - 4.11.1 TRANSMIT CODE ID

216 End Programming Format 1664 Barcode Scanner User Guide 6.3.3 MATCHING STRING & LOCATION By default, no matching string is specified, and the

Strona 144

217 Update Chapter 6 Applying Formats for Data Editing 6.4 CONFIGURING FORMAT — DEFINE DATA FIELD 6.4.1 START POSITION Data can be divided int

Strona 145

218 End Programming Format 1664 Barcode Scanner User Guide 6.4.3 TOTAL NUMBER OF FIELDS Data can be divided into at most 6 fields; each of them is n

Strona 146

12 Enter Setup 1664 Barcode Scanner User Guide DEFAULT SETTINGS SAVE USER SETTINGS AS DEFAULTS For the scanner to keep the customized settings as use

Strona 147

219 Update Chapter 6 Applying Formats for Data Editing 6.4.4 FIELD SETTINGS Data eligible for editing formats is divided into fields by user-s

Strona 148 -  GS1 DataBar Expanded

220 End Programming Format 1664 Barcode Scanner User Guide Field 2 Setting 1. Read the barcode below to divide field 2 by a specified terminating s

Strona 149 - Transmit Application ID

221 Update Chapter 6 Applying Formats for Data Editing Field 3 Setting 1. Read the barcode below to divide field 3 by a specified terminating

Strona 150 - 4.13.5 CONVERT TO UPC/EAN

222 End Programming Format 1664 Barcode Scanner User Guide Field 4 Setting 1. Read the barcode below to divide field 4 by a specified terminating s

Strona 151 - 4.14.2 TRANSMIT CHECK DIGIT

223 Update Chapter 6 Applying Formats for Data Editing Field 5 Setting 1. Read the barcode below to divide field 5 by a specified terminating

Strona 152

224 End Programming Format 1664 Barcode Scanner User Guide Additional Fields Up to five additional fields can be created for each editing format; ea

Strona 153 - 4.15 EAN-8

225 Update Chapter 6 Applying Formats for Data Editing 6.4.5 PAUSE FIELD SETTING Pause Field Time You can limit the pause time interval (1~16)

Strona 154 - 4.16 EAN-13

226 End Programming Format 1664 Barcode Scanner User Guide 6.5 CONFIGURING FORMAT — DEFINE TRANSMISSION SEQUENCE After configuring the data fields a

Strona 155 - 4.16.2 CONVERT TO ISSN

227 Update Chapter 6 Applying Formats for Data Editing Additional Field 2 Additional Field 3 Additional Field 4 Additional Fiel

Strona 156

228 End Programming Format 1664 Barcode Scanner User Guide 6.6 PROGRAMMING EXAMPLES 6.6.1 EXAMPLE I Extract data from the 10th character to the 19th

Strona 157 - 4.18 UPC-A

13 Update Quick Start READ A SETUP BARCODE CONFIGURE PARAMETERS For most of the scanner parameters, only one read is required to set them to ne

Strona 158 - 4.18.2 TRANSMIT CHECK DIGIT

229 Update Chapter 6 Applying Formats for Data Editing 6.6.2 EXAMPLE II Extract the date code, item number, and quantity information from barc

Strona 159 - 4.19 UPC-E

230 End Programming Format 1664 Barcode Scanner User Guide

Strona 160

231 Update Optical Characteristics 1664 Scan Engine 2D Imager Light Source Visible red LED RF Characteristics WPAN Module Bluetooth® Class

Strona 161 - 4.19.4 TRANSMIT CHECK DIGIT

232 Enter Setup 1664 Barcode Scanner User Guide Electrical Characteristics Battery Rechargeable Li-ion battery — 3.7 V, 850 mAh Power Adaptor Input

Strona 162 - 4.20.2 TRANSMIT CHECK DIGIT

233 Update Upgrade firmware to one scanner at a time. For example, turn off each of the rest scanners when there is more than one scanner connect

Strona 163

234 Enter Setup 1664 Barcode Scanner User Guide Enter Setup Download 5) Run the download utility “ProgLoad.exe” on your computer. Kernel

Strona 164 - 4.21.3 COMPOSITE TLC-39

235 Update Appendix I Firmware Upgrade USING DIRECT USB VIRTUAL COM 1) Use the provided USB cable to connect 1661/1664 to the USB port of PC.

Strona 165

236 Enter Setup 1664 Barcode Scanner User Guide Note: Because 1664 supports the downloading of firmware via Direct USB Virtual COM interface, the out

Strona 166 - 4.22.3 TRANSMIT CHECK DIGIT

237 Update Appendix I Firmware Upgrade  For the communication settings, select “RS-232” and the correct COM port for Bluetooth® SPP inter

Strona 167 - 4.23.2 TRANSMIT CHECK DIGIT

238 Enter Setup 1664 Barcode Scanner User Guide HOW TO UPGRADE 3610 FIRMWARE Connect 3610 to the USB port of PC after installing its driver. Refer to

Strona 168 - 157

14 Enter Setup 1664 Barcode Scanner User Guide The example below shows how to save your settings as “User Default” so that you may restore user defau

Strona 169 - 4.24.5 UPU FICS POSTAL

239 Update Appendix I Firmware Upgrade 4) Read the “Update” barcode for the scanner to resume its operation (exit the configuration mode). U

Strona 170 - 4.25.2 MicroPDF417

240 Enter Setup 1664 Barcode Scanner User Guide 3) The 3610 will automatically restart itself when upgrading firmware is completed successfully. 4)

Strona 171 - 4.25.3 DATA MATRIX

241 Update SERIAL COMMANDS D Purpose To disable the scanner. Remarks “D” E Purpose To enable the scanner. Remarks “E” #@ nnnnnn <CR> Purp

Strona 172 - 4.25.7 AZTEC

242 Enter Setup 1664 Barcode Scanner User Guide #@TRIGOFF<CR> Purpose To disable the software trigger Remarks “0x23” + “0x40” + “0x54” + “0x52

Strona 173

243 Update Appendix II Host Serial Commands  For the scanner to read the serial number and beep - #@RDSN<CR> #@////<CR> Note:

Strona 174

244 Enter Setup 1664 Barcode Scanner User Guide 3610 SERIAL COMMAND TABLE Config<CR> Purpose To configure 3610. Here is the setup barcode for

Strona 175

245 Update Appendix II Host Serial Commands UseVariablePort<CR> Purpose To use variable Virtual COM port when connecting more than one

Strona 176 - Chapter 5

246 Enter Setup 1664 Barcode Scanner User Guide EXAMPLE Without using the scanner to read the above setup barcodes for configuring the 3610 dongle, r

Strona 177

247 Update 0 1 2 3 4 5 6 7 8 0 F2 SP 0 @ P ` p  1 INS F3 ! 1 A Q a q  2 DLT F4 " 2 B R b r  3 Home F5 # 3

Strona 178

248 Enter Setup 1664 Barcode Scanner User Guide KEY TYPE & STATUS KEY TYPE If “Bluetooth® HID” or “USB HID” is configured for interface, Key Type

Strona 179

15 Update Quick Start The example below shows how to set numeric parameters: Steps Action User Feedback if Successful 1 Power on the scanner.

Strona 180

249 Update Appendix III Keyboard Wedge Table EXAMPLE KEY TYPE = NORMAL For example, if you want to program the character “!” as the prefix cod

Strona 181

250 Enter Setup 1664 Barcode Scanner User Guide

Strona 182

251 Update AbortDECIMAL SYSTEM Decimal Validate the Values Appendix IV NUMER

Strona 183

252 Enter Setup 1664 Barcode Scanner User Guide HEXADECIMAL SYSTEM Hexadecimal 0 1 2 3 4 5 6 7 8 9 A B C D E F

Strona 184

253 Appendix IV Numeral Systems Update AbortValidate the Values ASCII TABLE 0 1 2 3 4 5 6 7 0 DLE SP 0 @ P ` p 1 S

Strona 185

254 Enter Setup 1664 Barcode Scanner User Guide ENTERING PIN CODE FOR AUTHENTICATION USE PRESET PIN 1) In the configuration mode, read the barcode b

Strona 186

255 Appendix IV Numeral Systems Update AbortDISABLE AUTHENTICATION OR USE RANDOM PIN In the configuration mode, read the barcode b

Strona 187

256 Enter Setup 1664 Barcode Scanner User Guide 3. Read the “Validate” barcode to complete this setting. Reject Random PIN Request When the random P

Strona 188 - 177

16 Enter Setup 1664 Barcode Scanner User Guide The example below shows how to set string parameters: Steps Action User Feedback if Successful 1 Pow

Strona 189

17 Update Quick Start LIST THE CURRENT SETTINGS The current settings of all scanner parameters can be sent to the host computer for user inspec

Strona 190

18 Enter Setup 1664 Barcode Scanner User Guide List settings regarding Editing Format 1 (1/2) List Page 11 List settings regarding Editing Format

Strona 191

FOR USA This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These

Strona 192 - 181

19 Update Quick Start CREATE ONE-SCAN SETUP BARCODES The fact is most of the scanner parameters require only one read for setting new values. T

Strona 193 - 5.4.2 CHANGE CODE ID

20 Enter Setup 1664 Barcode Scanner User Guide

Strona 194 - 183

21 Update This chapter explains the features and usage of the barcode scanner. IN THIS CHAPTER 1.1 Battery...

Strona 195

22 Enter Setup 1664 Barcode Scanner User Guide 1.1.1 HOW TO OPERATE THE SCANNER Turn on the scanner… Press the [Power/Delete] key for 2 seconds. The

Strona 196 - 5.4.3 CLEAR CODE ID SETTINGS

23 Update Chapter 1 Understanding the Barcode Scanner 1.1.2 AUTO POWER OFF & POWER-SAVING The scanner will stay active at power-on, which

Strona 197 - 5.5 LENGTH CODE

24 Enter Setup 1664 Barcode Scanner User Guide After establishing a WPAN connection successfully… 1. Once a WPAN connection is established successfu

Strona 198

25 Update Chapter 1 Understanding the Barcode Scanner Auto Off after 0~254 min. (*10) 1) Read the barcode above to specify the time inte

Strona 199

26 Enter Setup 1664 Barcode Scanner User Guide 1.2 MEMORY The scanned data can be sent to a host computer immediately via the WPAN connection or stor

Strona 200

27 Update Chapter 1 Understanding the Barcode Scanner 1.2.2 MEMORY MODE When the scanner is in memory mode, it means any real-time connection

Strona 201

28 Enter Setup 1664 Barcode Scanner User Guide 8 sec Send Data When the memory is used up, the scanner will respond with two short beeps (high-lo

Strona 202

FOR HAND-HELD PRODUCT WITH RF FUNCTIONS The 1664 unit (FCC ID: Q3N-1664) complies with FCC radiation exposure limits set forth for uncontrolled envir

Strona 203

29 Update Chapter 1 Understanding the Barcode Scanner 1.3 LED INDICATOR The triple-color LED on top of the scanner is used to provide user fee

Strona 204 - Length Code for Aztec

30 Enter Setup 1664 Barcode Scanner User Guide 1.3.1 GOOD READ LED *Enable Good Read LED Disable Good Read LED 1.3.2 GOOD READ LED DURATIO

Strona 205 -  Code Type

31 Update Chapter 1 Understanding the Barcode Scanner 1.4 BEEPER The scanner has a buzzer to provide user feedback in various operating condit

Strona 206

32 Enter Setup 1664 Barcode Scanner User Guide 1.4.1 BEEPER VOLUME Mute Minimum Volume Medium Volume *Maximum Volume

Strona 207

33 Update Chapter 1 Understanding the Barcode Scanner 1.4.2 GOOD READ BEEP Frequency 8 kHz *4 kHz 2 kHz 1 kHz Duration *Sho

Strona 208

34 Enter Setup 1664 Barcode Scanner User Guide 1.4.3 LOW BATTERY ALARM By default, the built-in battery alarm will sound when the battery charge gets

Strona 209

35 Update Chapter 1 Understanding the Barcode Scanner 1.6 SEND “NR” TO HOST The scanner can send a “NR” string to the host to notify a No Read

Strona 210 - Chapter 6

36 Enter Setup 1664 Barcode Scanner User Guide 1.7 SCAN MODES Different scan modes are supported – select the scan mode that best suits the requireme

Strona 211

37 Update Chapter 1 Understanding the Barcode Scanner 1.7.2 AUTO OFF MODE The scanner will start scanning once the trigger is pressed.  The

Strona 212 - 6.1.2 EXCLUSIVE DATA EDITING

38 Enter Setup 1664 Barcode Scanner User Guide 1.7.4 AIMING MODE The scanner will aim at a barcode once the trigger is pressed, and start scanning wh

Strona 213 - End Programming Format

Version Date Notes 1.03 Feb. 06, 2012 Add: Chapter 6 fields of Time Stamp 1.02 Jan. 11, 2012 Modified: Specifications: Dimension and Weight d

Strona 214

39 Update Chapter 1 Understanding the Barcode Scanner 1.8 SCANNING TIMEOUT Specify the scanning time interval (1~254 sec.; 0= Disable) when th

Strona 215 - 6.2.2 RESTORE DEFAULT FORMAT

40 Enter Setup 1664 Barcode Scanner User Guide 1.9 DELAY BETWEEN RE-READ This is also referred to as the “Blocking Time”, which is used to prevent th

Strona 216 - 6.3.1 APPLICABLE CODE TYPE

41 Update Chapter 1 Understanding the Barcode Scanner 1.10 READ REDUNDANCY FOR ALL SYMBLOGIES Select the level of reading security. For exampl

Strona 217

42 Enter Setup 1664 Barcode Scanner User Guide 1.11 ADDON SECURITY FOR UPC/EAN BARCODES The scanner is capable of decoding a mix of UPC/EAN barcodes

Strona 218

43 Update Chapter 1 Understanding the Barcode Scanner 1.13 USING DIRECT USB CABLE 1664 supports Direct USB interface for charging the battery

Strona 219

44 Enter Setup 1664 Barcode Scanner User Guide 1.14 PICKLIST MODE Picklist mode enables the decoder to decode only the barcodes aligned under the cen

Strona 220

45 Update Chapter 1 Understanding the Barcode Scanner 1.16 TIME STAMP Specify time stamp format added to the prefix or suffix of a data. U

Strona 221

46 Enter Setup 1664 Barcode Scanner User Guide Date Output *Enable Date Output Disable Hour Output *Enable Hour Output Diable Minu

Strona 222

47 Update Chapter 1 Understanding the Barcode Scanner Decoding Data and Time Year Setup Date Setup Time Setup 1) Read the barcode

Strona 223

48 Enter Setup 1664 Barcode Scanner User Guide 1.16.3 DATE FORMAT The date format includes year, month and day. There are three kinds of combinations

Strona 224

CONTENTS IMPORTANT NOTICES ... -

Strona 225

49 Update Chapter 1 Understanding the Barcode Scanner 1.17 2D DECODE SETTING 1.17.1 AIMING PATTERN Enable/Disable the aiming pattern during sc

Strona 226 - 6.3.2 DATA LENGTH

50 Enter Setup 1664 Barcode Scanner User Guide 1.18 HARDWARE RESET 1.18.1 RESTORE SYSTEM DEFAULTS In addition to using the “Restore System Defaults”

Strona 227

51 Update In order to establish a proper connection between host computer and the scanner, we suggest following these instructions – 1) Instal

Strona 228

52 Enter Setup 1664 Barcode Scanner User Guide 2.1 BLUETOOTH® HID For Bluetooth® HID, refer to Chapter 3 – Setting up a WPAN Connection for related c

Strona 229 - 6.4.3 TOTAL NUMBER OF FIELDS

53 Update Chapter 2 Selecting Output Interface 2.1.1 ACTIVATE BLUETOOTH® HID & SELECT KEYBOARD TYPE When Bluetooth® HID interface is activ

Strona 230 - 6.4.4 FIELD SETTINGS

54 Enter Setup 1664 Barcode Scanner User Guide 2.1.2 RESET CONNECTION For Bluetooth® HID, you can only have the scanner connected to one computer at

Strona 231

55 Update Chapter 2 Selecting Output Interface 2.1.3 KEYBOARD SETTINGS  Alphabet Layout  Numeric Layout  Capital Lock Type  Capital Lo

Strona 232 - Field 3 Setting

56 Enter Setup 1664 Barcode Scanner User Guide US Keyboard Style – Normal QWERTY layout, which is normally used in western countries.

Strona 233 - Field 4 Setting

57 Update Chapter 2 Selecting Output Interface Numeric Layout Select a proper layout that matches the alphabet layout. The scanner will make

Strona 234 - Field 5 Setting

58 Enter Setup 1664 Barcode Scanner User Guide Capital Lock Type & Setting In order to send the alphabet with correct case, the scanner needs to

Strona 235 - Key Type Key Status

1664 Barcode Scanner User Guide 1.4.2 Good Read Beep ...

Strona 236 - 6.4.5 PAUSE FIELD SETTING

59 Update Chapter 2 Selecting Output Interface *Capital Lock OFF

Strona 237

60 Enter Setup 1664 Barcode Scanner User Guide Alphabet Transmission By default, the alphabet transmission is case-sensitive, meaning that the alphab

Strona 238 - 227

61 Update Chapter 2 Selecting Output Interface Numeric Transmission By default, the alphanumeric keypad is used for transmitting digits. Selec

Strona 239 - 6.6.1 EXAMPLE I

62 Enter Setup 1664 Barcode Scanner User Guide 2.1.4 INTER-CHARACTER DELAY By default, the inter-character delay is set to zero. Specify a value, ran

Strona 240 - 229

63 Update Chapter 2 Selecting Output Interface 2.1.6 HID CHARACTER TRANSMIT MODE By default, HID interface sends data to the host in batch. Yo

Strona 241

64 Enter Setup 1664 Barcode Scanner User Guide 2.2 BLUETOOTH® SPP SLAVE For Bluetooth® SPP Slave, refer to Chapter 3 – Setting up a WPAN Connection f

Strona 242 - SPECIFICATIONS

65 Update Chapter 2 Selecting Output Interface 2.2.3 ACK/NAK TIMEOUT By default, the scanner sends data to the host without waiting for an ACK

Strona 243

66 Enter Setup 1664 Barcode Scanner User Guide 2.3 BLUETOOTH® SPP MASTER As a SPP master device, the scanner will be able to resume connection with t

Strona 244 - Appendix I

67 Update Chapter 2 Selecting Output Interface Note: Read the “Set Connection” barcode first, and then the “MAC ID” barcode within 10 seconds

Strona 245 -  Click [OK]

68 Enter Setup 1664 Barcode Scanner User Guide 2.3.2 INTER-FUNCTION DELAY By default, the inter-function delay is set to zero. Specify a value, rangi

Strona 246 - Appendix I Firmware Upgrade

1664 Barcode Scanner User Guide 2.3.2 Inter-Function Delay...

Strona 247 - USING BLUETOOTH

69 Update Chapter 2 Selecting Output Interface 2.3.3 ACK/NAK TIMEOUT By default, the scanner sends data to the host without waiting for an ACK

Strona 248

70 Enter Setup 1664 Barcode Scanner User Guide 2.4 USB HID VIA 3610 For USB HID, connect 3610 to the USB port of PC, and then connect the scanner to

Strona 249

71 Update Chapter 2 Selecting Output Interface 2.4.1 ACTIVATE USB HID & SELECT KEYBOARD TYPE When USB HID interface is activated, you will

Strona 250

72 Enter Setup 1664 Barcode Scanner User Guide 2.4.2 KEYBOARD SETTINGS  Alphabet Layout  Numeric Layout  Capital Lock Type  Capital Lock Se

Strona 251

73 Update Chapter 2 Selecting Output Interface US Keyboard Style – Normal QWERTY layout, which is normally used in western countries.

Strona 252 - Appendix II

74 Enter Setup 1664 Barcode Scanner User Guide Numeric Layout Select a proper layout that matches the alphabet layout. The scanner will make adjustme

Strona 253

75 Update Chapter 2 Selecting Output Interface Capital Lock Type & Setting In order to send the alphabet with correct case, the scanner ne

Strona 254 - Host Serial Commands

76 Enter Setup 1664 Barcode Scanner User Guide *Capital Lock OFF

Strona 255 - 3610 SERIAL COMMAND TABLE

77 Update Chapter 2 Selecting Output Interface Alphabet Transmission By default, the alphabet transmission is case-sensitive, meaning that the

Strona 256

78 Enter Setup 1664 Barcode Scanner User Guide Numeric Transmission By default, the alphanumeric keypad is used for transmitting digits. Select “Nume

Strona 257 - EXAMPLE

1664 Barcode Scanner User Guide 4.6 Italian Pharmacode (Code 32)...

Strona 258 - Appendix III

79 Update Chapter 2 Selecting Output Interface 2.4.3 INTER-CHARACTER DELAY By default, the inter-character delay is set to zero. Specify a val

Strona 259 - KEY STATUS

80 Enter Setup 1664 Barcode Scanner User Guide 2.4.5 HID CHARACTER TRANSMIT MODE By default, HID interface sends data to the host in batch. Read the

Strona 260

81 Update Chapter 2 Selecting Output Interface 2.5 USB VIRTUAL COM VIA 3610 Connect 3610 to the USB port of PC, and then connect the scanner t

Strona 261

82 Enter Setup 1664 Barcode Scanner User Guide 2.5.3 ACK/NAK TIMEOUT By default, the scanner sends data to the host without waiting for an ACK/NAK re

Strona 262 - Appendix IV

83 Update Chapter 2 Selecting Output Interface 2.6 DIRECT USB HID 1664 supports “Direct” USB HID interface for memory mode. Use the provided

Strona 263 - HEXADECIMAL SYSTEM

84 Enter Setup 1664 Barcode Scanner User Guide 2.6.1 ACTIVATE USB HID & SELECT KEYBOARD TYPE When USB HID interface is activated, please select a

Strona 264 - ASCII TABLE

85 Update Chapter 2 Selecting Output Interface 2.6.2 KEYBOARD SETTINGS  Alphabet Layout  Numeric Layout  Capital Lock Type  Capital

Strona 265 - USE PRESET PIN

86 Enter Setup 1664 Barcode Scanner User Guide US Keyboard Style – Normal QWERTY layout, which is normally used in western countries.

Strona 266

87 Update Chapter 2 Selecting Output Interface Numeric Layout Select a proper layout that matches the alphabet layout. The scanner will make a

Strona 267 - Reject Random PIN Request

88 Enter Setup 1664 Barcode Scanner User Guide Capital Lock Type & Setting In order to send the alphabet with correct case, the scanner needs to

Komentarze do niniejszej Instrukcji

Brak uwag