CipherLab 1504 Podręcznik Użytkownika Strona 200

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 217
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 199
188
Enter Setup
1504 Barcode Scanner
User Guide
#@TRIGOFF<CR>
Purpose Disable software trigger
Remarks
“0x23” + “0x40” + “0x54” + “0x52” + “0x49” + “0x47” + “0x4f” + “0x46” + “0x46”
+ “0x0d”
#@TRIGON<CR>
Purpose Enable software trigger
Remarks
“0x23” + “0x40” + “0x54” + “0x52” + “0x49” + “0x47” + “0x4f” + “0x4e” + “0x0d”
EXAMPLE
Run HyperTerminal.exe on the host computer to send serial commands to the scanner
via RS-232 or USB Virtual COM.
For the scanner to stop immediately –
D
For the scanner to resume working –
E
For the scanner to change the beeper to medium volume and beep –
#@101011<CR>
#@////<CR>
For the scanner to change the beeper to minimal volume and beep –
#@101010<CR>
#@////<CR>
For the scanner to change the beeper frequency to 8 kHz (for Good Read Beep only)
and beep –
#@101001<CR>
#@////<CR>
For the scanner to change the beeper length to longest (for Good Read Beep only)
and beep –
#@101008<CR>
#@////<CR>
For the scanner to save the settings, send the serial command “#@109999” –
#@101011<CR>
#@109999<CR>
Note: Configure more than one scanner connected to the host via RS-232 or USB Virtual
COM. To identify the scanner, please end the serial command to have it respond
with a beep.